whessoe tank gauge. 2016 (36m), Model No. whessoe tank gauge

 
 2016 (36m), Model Nowhessoe tank gauge  101,526

Get comprehensive list of Level Gauges dealers UAE, Level Gauges branded products, agents, distributors, search brands in UAE brand directory - atninfo. SKU: 1014377 | Item ID: WEM UP2WH. Remove the gauge from the gauge pipe and place the new gauge inside. This includes instruments that operate accurately under cryogenic conditions. Flow Measurement. Tank Gauging System. 1. mesc. The tape extends into the tank and is secured to a float of critical weight. AP Products - Ideal for RV - Works for horizontal tank - 16, 20, 30, 40, and 100 lbs: Sonar. 7,000 bar / 8. When the pressure in the wet tank reaches 120 psi the air governor sends an air signal to the unloader port which goes to the air compressor head and dryer. (Note: you must gauge the product to the closest 1/8 inch. Find the end of the old float gauge arm and pull it from the oil tank with a piece of wire. Lockdown device allows for a gas-tight seal up to 3 psig (20. Maximum five gauges, type Rosemount 5300 or. 28. , a define used to measure the level of fluids. The Whessoe - Varec Vapour Control range of Pressure and Vacuum relief valves cover a wide range of settings and materials to satisfy all the requirements of the liquid storage industry. Varec, a wholly owned subsidiary of Leidos, is a leading innovator in inventory management applications to automate bulk liquid management at tank farms, marketing terminals and fuel distribution points within the oil and gas, defense & aviation industries. From there, multiply the number of gallons by the gauge’s percentage to get a feel for how much propane is left. The Tank Scanner NXA820 supports different field protocols (Modbus EIA485, Sakura V1, Whessoe WM550). Independent safety layers are used for both prevention and mitigation. Protocol Electrical. Definition Absolute Pressure. KM26 MAGNETIC LEVEL GAUGE | OI/KM26-EN REV 3 This manual is designed to provide information on installing, operating and troubleshooting or maintenance of the KM26 family of magnetic level gauge (MLG). Threads below the adjustment knob and an included panel-mount nut allow you to add these valves to your instrument panel. 123 products. Office Hours EST. In this respect, Servo tank gauges are similar to mechanical float measurements. The deformation would otherwise result in undesirable vertical movement of the tank roof and, hence, a change in the gauge. 15. A: The gauge on this tank is not a pressure gauge, it is an accurate gauge that is activated by a magnet that reads the actual gas levels inside the tank. VISUALLY INSPECT THE SENDING UNIT / TEST. Whessoe – Varec Vapour Control are constantly developing their range of products, therefore additional sizes, additional materials and settings outside the normal range can be offered. The reference gauge height is the distance from the reference gauge point (a fixed point on the top of the tank) to the datum plate at the bottom of the tank, as shown in Fig. The bolt pattern is a marine standard so for replacement we just need to know the length of the sender. They are used for measuring the depth of ullage space in an oil tank. Level Gauges for LNG tanks. This is an Argon / CO2 regulator and flow meter coming from BETOOLL. Over time, parts can wear out or become damaged due to mishandling, exposure to the elements, or manufacturing defects. When redundant communication is required the gauge can communicate via different protocols or buses. Gauge Table - See Calibration Table. where p abs is absolute pressure, p g is gauge pressure, and p atm is atmospheric pressure. A. 0 - 30. Choose from our selection of tank level indicators, including liquid-level gauges, liquid-level indicators, and more. A. iii Safety Precaution Definitions Caution! Damage to equipment may result if this precaution is disregarded. Orange County UK - leading specialist in industrial piping solutions and leak detection equipment. If your wiring and fuse test as passed, usually the next option is to remove the fuel sending unit / fuel pump assembly from the tank and inspect. 1. magnetic for tank threaded. A specific valve brand is selected, according to pressureTanks A guide for owners and operators of USTs This is module g of the PST Super Guide, a comprehensive guide to issues relating to petroleum storage tanks (PSTs). Join Neighbor's Club. Whessoe® digital current loop or RS485 TankRadar Rex has the ability to connect directly to the Whessoe digital current loop or Whessoe RS485. This prevents ingress of the tank contents into the indicator capsule. Whessoe’s scope included the following major elements: Refurbishment and major upgrade of existing Jetty No 1 dedicated to unloading LNG carriers from 71,500m³ up to 250,000m 3. A float inside the tank is connected to an indicator in a clear tube mounted outside of the tank. Taiwan, and Turkey, which supply 98%, 1%, and 1% of tank gauge system. 15 gauges • Protocol compatible to Scientific Instruments (RS485), max. 1 engine on the North Western Railway. Unit electronics are isolated from the tank atmosphere and existing float gauge fittings can be reused. Gauge Point - See Reference Point. Anderson Greenwood Whessoe 4110 Pressure and Vacuum Relief Valves. C. The SAAB REX measures levels to a precision of ±0,5 mm, can emulate level gauges from other manufacturers and can be fully integrated into existing systems. It can be calibrated in gallons or fractions of a full tank that can be read by the pilot. Additionally, when your propane tank is full, it will read 80%, not 100%. Our roots were built from the iron and steel industries of the Northeast of England, the engineering legend Whessoe, and Varec, the original pioneer for tank gauging and inventory management in the USA. Available in 2 options. the antenna is inside the tank atmosphere. 1) (11. The FCU2165/2175 must be set to use the same baud rate as the Outstations / Transmitters on the Loop. Varec continues to provide tank gauging, inventory control systems, SCADA and other fuel management solutions for the oil & gas, aviation and defense industries. In many cases, our sales representatives also represent other manufacturers in the oil, gas and petroleum. However, such fear of gas influence on radar signals is unfounded. send data from a group of tanks to a TankMaster PC or a host. For example a 73-10 ohm fuel sender would read backwards on a 0-90 ohm fuel gauge. It is used in various applications across varied industry verticals, which includes oil & gas, metal & mining, chemical, automotive, and power generation industry. The indicator moves up and down based on the level of product in the tank. Any sudden increase in the water level may indicate a leaking tank or a leaking tank top fitting. Monitoring tank inventory levels traditionally involved two operators, one in the field and one in the control room. A Rosemount 5900 level gauge in combination with a 2410 Tank Hub enables wireless communication and emulation of gauges from other manufacturers. 101,526. mesc. Mon - Fri 8:30AM - 5:30PM. Basic & Detailed Engineering. To add the ultrasonic water level sensor to Home Assistant for monitoring, follow these steps: In Home Assistant, go to Configuration > Devices and Services. The FCU2165/2175 must be set to use the same baud rate as the Outstations / Transmitters on the Loop. Molded float is impervious to petroleum products. If not, click Add Integration. 2. Basic & Detailed Engineering. Each of these independent representatives support our customers with the same level of quality and unwavering dedication demonstrated by our own employees. Whessoe executed the detailed tank design of the two 150,000m 3. In Stock. Tank gauging, level gauging – the process of measuring tank contents. LNG has evolved into a major source of energy for the future, and Wartsila Tank Control Systems can supply your site with the only turnkey LNG tank gauging and storage management system available. Tape material: SST. Sakura V1 or Whessoe 550 field protocols. Marine Cargo Monitoring System; 26. Installs through 2” schedule 40 pipe or 2” tank bung. If the gauge rises above the middle, the car is at risk of overheating. 016 in). Interstitial Monitoring. Tank gauging means liquid measurement in large storage tanks to determine product volume. Also known as oil-gauging tapes, use these tape measures to check the level of oil and other fluids in deep, large containers such as tanks and vats. to the reference gauge point of the tank. 8211 Current Loop Interface Module using Whessoe Bus Protocol Installation and Operations Manual . General Description of Air Brake Systems and FMVSS No. Varec is able to provide an alternative,Automatic Tank Gauges. Why are gauge pressure gauges with Bourdon tube used for relative pressure (0. Multi-Element Temperature Transmitter. This means that it is possible to replace the2 B a dia. Anglo American Oil Company Ltd as Wauhatchie - US Flag. roof of the tank is floating freely and the point where it. g. Compare Compare Anderson Greenwood Marvac 785/786 Manhole Cover. In Stock. IMPORTANT: When you move the drop tube inside the tank riser pipe, do so slowly and carefully to help prevent the drop tube from impacting the riser pipe. 04 Density meters. SI-7000 LTD by Scientific Instruments is the dependable solution for level, temperature, and density profiling in LNG & LPG Storage Tanks. NOTE: The gauge will not let you calibrate the tank until the capac- ity had been entered). Choose from our selection of temperature gauges, including threaded thermometers, steam pressure gauges, and more. Mount these gauges on the flat end of a horizontal, cylindrical tank to monitor diesel fuel, fuel oil, or gasoline level. 2. The reverse float level system can be used on almost any tank, including double-walled SAFE-Tanks. The Manzanillo LNG Regasification terminal is located in Colima, Mexico, which is a highly seismic area close to the west coast fault line. The Tank Scanner NXA820 supports different field protocols (Modbus EIA485, Sakura V1, Whessoe WM550). This gauge has broken cover and needs replacement. Match the type of dial to the type of gauge cup: Tabbed (pg 2), Drop-in (pg 3), Snap-on (pg 4), and press-in (pg 5) 3. Study now. Radar is today used on more than 8,000 LPG and LNG tanks worldwide with excellent results and proven track records. Look at where the top of the disc lines up with the tick marks to determine the current level in the tank. Float & Tape Tank Gauging Overview CrossCo. There is a plastic vial with a disk that indicates how full the heating oil tank is. Whessoe, Jaugeur Asseryi Type 1140, FIG. 4. It integrates other instruments, performs tank side calculations and shares data from the field to the control room. A. A sight glass is a clear glass or plastic tube open to the fuel tank that fills with fuel to the same level as the fuel in the tank. PDF. It can also be used on horizontal tanks up to 30 inches in diameter. Shop Hydraulic Level Gauges available online now at Hydrofitme. Ch. This fuel oil tank gauge features an arm with a float attached to its end, and a hinge. SI-7000 LTD by Scientific Instruments is the dependable solution for level, temperature, and density profiling in LNG & LPG Storage Tanks. It is a. 5. WORKS WITH MOST TANKS: Compatible with standard steel 138, 220, 240, 275, 330 (vertical or horizontal), 500 gallon tanks, and more. 2001 From Tank Farm to Take OffAutomatic Tank Gauge. Step 6: Record the Readings. ) instrument accuracy, reducing level measurement uncertainty to a minimum. 3a Typical. In stock and ready to ship. Whessoe WM 550/660 (digital current loop) G (1) GPE 31422/31423 (digital current loop). Whessoe (which was formed in Darlington in 1790) was acquired by Svanehoj in 2022. 2010. The tape drum, being spring loaded, provides a constant tension on the tape, regardless of the amount of tape paid out. With the FCU it is possible to con-2500 Automatic Tank Gauge Manual. Once open, the cover can remain open for ease of use. To make sure it fits your existing tank fittings, we have a wide. Either will give you the cubic feet per hour (CFH) or litres per minute (LPM) reading you seek. Buy a variety of water tank gauges for sale online at Tanks. 2. Wärtsilä Corporation, Press release 17 September 2021 at 11:30 UTC+2. Whessoe WM550) 11 Micropilot 12 Prothermo 13 Tank Side Monitor 14 Proservo 15 Promonitor The system can be designed in redundant mode. Rochester’s Hall Effect. Use of the Whessoe Tank Gauge. With the Gauge Link the Tank Scanner becomes a fit-for-purpose interface unit to the tank gauges with Enraf BPM and Emerson TRL/2 Protocols. "A quality. Whessoe rollover predictor DCS LNG Manager LNG Manager9510 20 mA loop / RS232C 9510 20 mA loop /. whessoe gague oloibiri 1979. Get in contact with the team for more information. Innova 3640 Professional Fuel Injection Pressure Tester. Yet even the holiest of men succumb to the darkest of temptations. We are the only authorized supplier of Whessoe spare parts. Download Resource. Tankvision Professional NXA85 6 Endress+Hauser• Redundant servo level gauges<br /> • High/high level alarm gauge<br /> • LTD gauge<br /> • Product spot temperature sensing<br /> elements<br />. The pious Ishgardian clergy guide the flock, and the devout knights protect the weak. I think this is applicable for flat bottom LNG storage tank. The gauge has passed seismic testing and is certifi ed to withstand a 12 g acceleration force. 2 model 1146 ltD gauge The world’s most advanced LTD gauge, this is also based on Wärtsilä Tank Control Systems’s unique single body concept. 3304 (40m. Enardo 2000: Varec Series 221 Emergency Pressure Relief Manway covers. Performance Floats. II. 0 - 17. In Stock. 8. , a UK based holding company, focusing on heavy engineering and tank gauging instrumentation and safety systems. e. Whessoe’s Scope: Engineering, Procurement, Construction, Commissioning . This method is a very precise way to read your propane tank levels. It was also the first to provide a level, temperature and density (LTD) gauge for floating storage. from €172. The NMS80 Proservo Tank Gauge (PTG) is an intelligent tank gauge for high accuracy liquid level measurement and is suited for both custody transfer and inventory management applications employing the latest microprocessor technology. Tank Gauging System. Application. The distance from the surface of the liquid in the tank. Thanks to the predictor you are able to make the right decisions at the right time, and to manage4. ie. Engine Instrument Wiring Made Easy. Fig. Easy to install with single vertical pipe connection. Learn. Rosemount 5900S Radar Level Gauge E. The world’s most advanced LTD gauge, this is also based on Wärtsilä Tank Control Systems’s unique single body concept. It meets the relevant requirements according to OIML R85 and API 3. 5 High Expansion Foam System May 2017 6. Note that some self-test steps may stop the gas gauge at 1/4, 1/2, and 3/4, as well. Magnetic tank level indicators tend to cost $6 to $8. It is ideally suited for tank farms with various protocols used for. 2. As global industry moves toward cleaner and greener processes, we are meeting the challenges to provide innovative storage tank safety and environmental solutions. LSG-77th-Minutes-7 Dec 2012. Supplying industries which include Oil & Gas, Petrochemical, food, water and Biogas. The optical reference line method is an alternative to the manual tank strapping method for determining tank diameter. Keep Your Propane Tank Level: Keeping the tank level helps ensure that the gauge accurately reads the amount of propane left in the tank. The tank owner should monitor the water level in tanks. WHESSOE VAREC GAUGING & SYSTEMS UNIVERSAL GAUGE TRANSMITTER Choose options from the suffixes to complete the order code. The measurements can be made under extreme environmental conditions with respect to temperature, pressure and. tank level gauge "endress+hauser" withtransmitter type:at 1120w f/ :60742. View All Measurement Instrumentation Products BRANDS Flexim. GSPC LNG Limited. 3-2. LNG Tank Gauging Systems. • Sakura V1, max. , LTD. A. Upgrades can proceed as the situation demands and when budget is available. The Tank Check system is a battery powered sensor that attaches with built-in magnets to the bottom of your RV’s propane cylinder (s). Please note that the brand names of pressure relief devices covered (Anderson Greenwood, Crosby, Whessoe and Varec) are of Emerson manufacture. The Rosemount 2410 Tank Hub supports the Whessoe protocols WM550 and WM660. • The Tank Scanner NXA820 connects multiple tank gauges: from up to 15 tanks via one field-loop. Symptoms of a broken gauge can include erratic readings, a. GSI designed the 2000 Encoder to be the most reliable and accurate encoder on the market. 1974 Whessoe Systems and Controls developed a gauge to measure the levels of liquefied gas, lpg and chemicals which was adaptable for both land and sea. The 2920 Float & Tape Transmitter (FTT) provides data from the tank side to the control room for use in inventory management applications. You can set the sensor to take a reading between every 1 to 24 hours. our history. The type approval of the WHESSOE servo level gauge model 01143 Mark II, demonstrates that the product used standalone is suitable for safety related functions up to SIL 2 integrity level in low demand and SIL 3 in high demand modes of operation, according to IEC 61508 parts 1 to 7, second edition, 2010. The distance between the point where the floating. The gauge may be specified as a top or side-mounted variant. The Total LNG Storage Tank Solution Whessoe S. 4590 Tankside Monitor. Oloibiri 1979. Toll Free: 1-800-466-6031. Whessoe 4020A Pressure and Vacuum Relief Valves. • The measured values are transmitted by the network and visualized on HTML pages. Location. For a detailed. 2 x 24,000m 3 Ethylene Tank with Associated Vaporisation Facilities. Air tanks. The intelligent tank gauge Proservo NMS8x is designed for high accuracy liquid level measurement in custody transfer and inventory control applications with NMi- and PTB-approvals. UNITEL HYDROSTATIC TANK GAUGE 20M. 2. 2d GMS Parameters May 2017 5. ParametersFigure 1-1 Whessoe Varec Model 6840 Tank Polling Unit. The inventory control system in the control room can then calculate volumes that are temperature corrected. One is a build-up of dirt and debris on the unit. e. 5 gallons of propane. 5 MMT/Yr LNG Import Terminal and Regas Plant with 2 x 180,000m³ Full Containment LNG Tanks, including Jetty Marine Works. Brands. The gauging of a plate or member normally starts out with two readings. The reliability and functionality of the Whessoe Varec Model 6840 Tank Polling Unit is dependent upon proper installation and location. Svanehoj Tank Control Systems is an integral part of Svanehoj and was established in Calais, France in 1961 as Whessoe plc. Model 1146 LTD Servo Gauge. Filing history for WHESSOE TOTAL AUTOMATION LIMITED (09764892) People for WHESSOE TOTAL AUTOMATION LIMITED (09764892) More for WHESSOE TOTAL AUTOMATION LIMITED (09764892) Registered office address Spinnaker House, Waterside Gardens, Fareham, England, PO16 8SD . 1. The Basic Process Control System (PBCS) and the Overfill Prevention System (OPS) provide continuous. These devices allow oil tanks to be filled to capacity without overfilling due to their loud alarm or large display. Varec’s sales and service network is comprised of over 40 companies worldwide. FT-1000/FP-1000. NOTE: This product is approaching its end-of-life status. Get instant access to inventory data with. 20 lbs. Total LNG Tank Instrumentation Solution Whessoe S. Pages: 8The first step would be to make sure that you have the proper ohm range fuel sender to match your gauges. Gauge/ Dip Hatches Tyco reserves the right to change the content without notice WEVDR-0002-EN-0210 The Whessoe - Varec Vapour Control 5071A & 5072A dip hatches are designed to provide tank access where manual level gauging, temperature measurement or sampling is required. NXA83B is a dedicated tank inventory system. The indicator moves up and down based on the level of product in the tank. Earn Rewards Faster with a TSC Card! Credit Center. Wärtsilä Whessoe LNG & FLNG Tank Gauging System. This simple and reliable float and tape based product has been used for managing inventory in the oil and gas industry for more than 80 years. All LNG Tank Instrumentation Supplied From A Single Source • Redundant servo level gauges • High/high level alarm gauge • LTD gauge • Product spot temperature sensing elements • Temperature element transmitters • Data handling / control software • LNG tank management. “cold day” distinction) Long stem can be a little bulky to fit on some grill models. Radar Tank Gauges Magnetostrictive Tank Gauge Tank Side Monitor or Display Servo Tank Gauge Guided Wave Antenna Planar Antenna (Stilling Well) Small Horn Antenna Parabolic. 361. KunLun Automatic Tank Gauge System are mainly used in underground oil. If your gauge has color coded hook-ups, maintain this coding as. The amount of use will vary depending on your grill and BTUs per hour. For example, if a tire gauge reads 34 psi, then the absolute. Outlet adapter on the 2020B Series is one pipe size larger than the valve inlet flange to optimize flow capacity. Features Pressure settings 2. Zero product loss when combined with a vapor recovery system. Causes and symptoms: Mechanical failure is one of the most common reasons for a malfunctioning propane tank gauge. Current Loop (Whessoe Bus) Current Loop (GPE) SAAB (TRL/2) Enraf (811, 802/812, 854, 873) L&J Tankway (MCG 1000, MCG. PDF. Enraf Nonius Delft, Specification Sheet 802-1-E, Solid State Reliability with Enraf 802 Series Precise Level Gauges, Nov. *2 : ADC12 (aluminum casting ) for screw connection versions *3 : Indicator support can be supplied as optional parts on request. An innage gauge is a direct measurement of liquid level. Table 1-1: Whessoe Protocol Options. 15. This tank is equipped with an extra tube inside which has a magnet on the end of it. Tanks greater than 2,000 gallons in capacity may not use this method of leak detection to meet these regulatory requirements. Operating Temperature: -40°F to 176°F (-40°C to 80°C)For pressure gauges with a pointer stop, the accuracy class applies from 10 to 100 % of the scale range. 72 inc VAT) We offer a range of water tank gauges from clock gauges to water level gauges and water meters. Propane tanks are filled to 80% capacity of the tank to allow for expansion of the liquid propane. This propane tank gas gauge can convert your old style connection type propane tank to new type (type1 / QCC1), it can be worked with propane tank cylinders, propane regulator with hose and propane adapter ; Fit for-rv camper cylinder converter, 20 30 40 or 100lbs propane tank. All LNG Tank Instrumentation Supplied From A Single Source • Redundant servo level gauges • High/high level alarm gauge • LTD gauge • Product spot temperature sensing elements • Temperature element transmitters • Data handling / control software • LNG tank management. Standard Features. The smart oil gauge will send you a text and/or e-mail alerts when it's time to order oil, or when the level reaches 1/2, 1/3, 1/4 and/or 1/8 of a tank full. Air tanks Air from the compressor is stored in air tanks. Reconnect all electrical connectors and snap fuel lines back in place. Integrity and operability of the gauge remain after the event, ensuring ahigh level of plant safety. nioc kala. Read the description printed on the dial face to choose the proper dial. Designed to assist the user in the installation, operation, maintenance, and troubleshooting of low-pressure 2500 Automatic Tank Gauges. Whessoe® digital current loop or RS485 TankRadar Rex has the ability to connect directly to the Whessoe digital current loop or Whessoe RS485. The Model L61T Gauge Hatch incorporates “cushioned-air” seating which assures a superior seal to ensure minimal. BETOOLL HW9003 Argon/CO2 Mig Tig Flow Meter Gas Regulator. Over a number of years, Whessoe Varec has developed the largest installed base of float gauges in the world, and the 2046 ATG provides a cost effective upgrade to these and other manufacturers’ float gauge installations. A typical Whessoe tank gauging system consists of a number of field devices such as level, temperature, and pressure devices. If the fuel sending unit uses screws, be sure to use the included washers to prevent leaks, and tighten in a star pattern. scans parameters from tank gauges and performs tank calculations • Tankvision Data Concentrator NXA821 summarizes data from various Tank Scanners NXA820 • Tankvision Host Link NXA822 provides data to host systems (such as PLC or DCS) via Modbus. Engine instrument gauges fall into three categories, and there are differences in the terminals and wiring. Measurement verification while tank. Best 2-Way Splitter: GASLAND Propane Tank Gauge. Fuel Level Indicator Tank Gauge. Servo level gauges 01140, 01141, 01142;See all our business classifications and business categories list (A-Z). Wärtsilä Whessoe LNG & FLNG Tank Gauging System. Non-contacting radar gauges, such as the Rosemount 5900S, measure the LNG level in the tank without any physical contact with the LNG surface, and without the. where Pabs P a b s is absolute pressure, Pg P g is gauge pressure, and Patm P a t m is atmospheric pressure. This functionality is expanded by the Gauge Link for the Enraf BPM and the Emerson TRL/seamless integration of tank gauges from different vendors. The Field Communication Unit can service requests from any hosts and/or DCS systems using the Modbus protocol. 1. 7. The gauge has passed seismic testing and is certifi ed to withstand a 12 g acceleration force. Reinstall the retaining ring (if applicable). 20. Figure 3 shows the Rosemount 2410 Tank Hub connected to an Emerson Wireless 775 THUM Adapter assembly with integrated. This means that you can position a dp cell at the top of the tank and the end of the tube at the bottom of the tank. View All Measurement Instrumentation Products BRANDS. Varec was a key component of the Whessoe Group of companies during the 1980s and 90s. Upgrade Choice: Camco Propane Gauge/Leak Detector. The 2100 eliminates problems found within other manufacturers’ brush and optical. Multiple tank version: for a Rosemount 5300/5400/5900 system configuration: The software supports 16 field devices and 10 tanks per hub. If it’s not working properly, it can cause the fuel gauge to give a false reading. Spring-balanced and Servo-balancing Type Tank Gauges; 28. 2100204172 206 GAUGE HEAD INCLUDING 30MTR TAPE(ENGLISH VERSION). LNG has evolved into a major source of energy for the future, and Wartsila Tank Control Systems can supply your site with the only turnkey LNG tank gauging and storage management system available. Sat - Sun Closed. Supplier of measuring tools and measuring gauges in Dubai - UAE. None dare to administer justice to these sacrosanct elite residing outside the reach of the law. The level gauge selected depends on the product application at hand. 16139-03-1 HYDRAULIC SAFETY VALVE REPAIR KIT 3". Connects easily without tools and fits on all. 1.